Room size
Ventilation
opening
Smaller than 5 m
3
min. 100 cm
2
5 m
3
to 10 m
3
min. 50 cm
2
Greater than 10 m
3
not required
In the cellar or basement min. 65 cm
2
Note.This appliance is supplied ex-factory with
jets and air settings for use with LPG gas only.
Safety compliance with local requirements:
Installation
A stove without a flame failure device may only be
used with a free standing cylinder placed adjacent
to but not closer to 300 mm to the stove.
Ensure that pipe clamps are tightened correctly and
are of a good quality.
Flexible hose -
Any hose that is used to connect the stove to the
gas system shall comply with SANS 1156-2 or BS
3212.
Gas cylinder - Not supplied.
For best results we recommend that gas cylinders
with a minimum capacity of 9kg be used.
Regulator -
A 2.8-3.0 kPa LPG gas regulator which complies
with SANS 1237 must be used.
Failure to comply with the above will render the
warranty invalid.
IMPORTANT INFORMATION FOR THE INSTALLER.
This appliance may only be installed by a gas installer
registered with the South African qualification and
certification committee (SAQCC).
The appliance must be installed in accordance with
the requirements of SANS 10087-1for use with LPG,
SANS 827 for use with NG and any fire department
regulations and/or local bylaws applicable to the area.
If in doubt, check with the relevant authority before
undertaking the installation. Upon completion of the
installation you are required to fully explain and
demonstrate to the user the operational details and
safety practices applicable to the appliance and the
installation.
Important information
Upon completion of the installation ensure that you
are familiar with the following:
a) The position of the isolation or shut-off valve in the
gas supply line to the appliance.
b) The requirements for safe operation of the
appliance.
IMPORTANT INFORMATION FOR THE USER
This appliance may only be installed by a
registered SAQCC Gas installer. All registered
installers are issued with a card carrying their
registration number. Ask to be shown the card before
allowing the installation work to commence and make
a note of the Installer registration number. Upon
completion of the installation, the installer is required
to explain the operational details of the appliance
together with the safety instructions. You will be asked
to sign acceptance of the installation and be provided
with a completion certificate. You should only sign for
acceptance of the installation when the installation is
completed to your satisfaction.
Note that your invoice is required in the event that you
wish make a guarantee claim.
Before connecting the gas hose, make sure that the
gas hose outlet behind the product is in the same
direction as the hose outlet
If the gas hose is not in the same direction as the
hose outlet, mount it so that it does not pass through
the hot zone when connecting the hose.
3
3
X
X
X
Routing of the gas hose