Installation instructions, RT-2
Page 3 of 11 4189350013C (UK)
Power supply H
DC voltage: 12...33V
(Polarity reversal protection.
The voltage must not fall below 12V.)
Max. residual ripple: 10% p.p.
Max. current
consumption: Approx. 5mA + I
A
Mechanical withstand
Permissible vibration: 0...200Hz,
10 g continuous, 15 g for 2 h
200...500Hz,
5 g continuous, 10 g for 2 h
Shock: 3 x 50 g every 10 impulses in all 3 axes
Permissible static load
on the shaft: Max. 1000N (radial)
Max. 500N (axial)
If subjected to vibration the shaft load should be as low as
possible to ensure optimum life of the bearing.
Mounting position: Any
Material
Housing (main part): Steel
Finish QPQ
(nitro-carbonated)
Rear (cover): Metal (aluminium)
Cable glands: Metal
Regulations
Test voltage: 500Veff, 50Hz, 1 min.
all electrical connections against housing
Housing protection: IP66 acc. to EN 60 529
Environmental conditions
Climatic rating: Temperature 25 to + 70°C
Annual mean relative humidity 90%
Transportation and
storage temperature: -40 to 80°C