ADJUSTING THE TEMPERATURE
The flow rate is pre-set at the factory at 3 lpm (at 3 bar). Adjust directly on the flow straightener
(with adjustable flow rate) using a 2.5mm Allen key:
- notch n°1 = 3 lpm (at 3 bar).
- notch n°2 = 4 lpm (at 3 bar).
- notch n°3 = 5 lpm (at 3 bar).
REMEMBER
Our mixers/taps must be installed by professional installers in accordance with current
regulations and recommendations in your country, and the specifications of the fluid engineer.
Sizing the pipes correctly will avoid problems of flow rate, pressure loss and unwanted noise
(see calculation table in the brochure and online at www.delabie.com).
Protect the installation with filters, water-hammer absorbers and pressure reducers to reduce
the frequency of maintenance (recommended pressure: 1 to 5 bar).
Install stopcocks close to the mixer to facilitate maintenance.
• The pipework, stopcocks, bib taps and all sanitary fittings should be checked at least once a year,
and more frequently if necessary.
MAINTENANCE AND CLEANING
Cleaning chrome
Do not use abrasive, chlorine or acid-based cleaning products. Clean with soapy water using a cloth
or a sponge.
Frost protection
Drain the pipes and operate the mixer several times to drain any remaining water.
EN