V0812, 4.6
4.5. Computation settings
4.d
Data preparation bend allowance . . . . . . . . . . . . . . . . . . . . . . . . . . . .BA
0 = correction off
1 = correction on
With this parameter you can choose whether or not you wish to have programmed
values corrected for bend-allowance. This on/off setting only refers to corrections during
product programming of a new program in the menu ‘program edit’. If a numeric
program has been entered with corrections on, the axis corrections are calculated and
stored in the program. These corrections can be viewed and edited in production mode
(see ‘Automatic mode’).
Bottoming Force Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .BF
The pressure needed for an airbend multiplied by this factor in order to obtain the
coining pressure.