Section 2 Installation
GROUND FAULT CIRCUIT INTERRUPTER
Ground Fault Circuit Interrupter (GFCI/GFI) protection is
a system that shuts down the electric circuit (opens it)
when it senses an unexpected loss of power, presumably
to ground. Welbilt does not recommend the use of GFCI/
GFI circuit protection to energize our equipment. If code
requires the use of a GFCI/GFI then you must follow the
local code. The circuit must be dedicated, sized properly
and there must be a panel GFCI/GFI breaker. We do not
recommend the use of GFCI/GFI outlets to energize our
equipment as they are known for more intermittent
nuisance trips than panel breakers.
Refrigeration
Model
BTU/Hour
Capacity
Heat of
Rejection
Charge
Base Rail Base Rail R290
F18MC27-BSNP
1494 1329 244 540 150g
F18MC27-BSP
1494 1329 244 540 150g
F18MC32-BLSP
1494 1025 263 360 150g
F18MC32-BSMP
1494 1019 263 304 150g
F18MC32-FSP
1494 1483 263 720 150g
F18MC33-BLSNP
1494 1025 263 360 150g
F18MC33-FSNP
1494 1483 263 720 150g
F18MC33-SCSP
1494 607 263 180 150g
F18RC32-FSP
1494 1025 263 360 150g
F18SC27-DCP
1494 834 244 270 150g
F18SC32-FSP
1494 1025 263 360 150g
Drain Connections
n
Warning
If a refrigerated base does not have a condensate
evaporator supplied, you must connect the condensate
line to a suitable drain. Otherwise, water will collect on
the floor, causing a potentially hazardous situation.
n
Warning
Moisture collecting from improper drainage can create a
slippery surface on the floor and a hazard to employees.
It is the owners responsibility to provide a container or
outlet for drainage.
Caster Installation
DANGER
Casters must be installed and screwed in completely to
prevent bending. When casters are installed the mass
of this unit will allow it to move uncontrolled on an
inclined surface. These units must be tethered/secured
to comply with all applicable codes.
n
Warning
The unit must be installed in a stable condition with
the front wheels locked. Locking the front casters after
installation is the owner’s and operators responsibility.
,
Caution
If casters are replaced, the unit must stand upright for
twenty-four (24) hours before being powered up to
assure oil return to the compressor sump.