EasyManua.ls Logo

Dell EMC PowerVault MD3820i - Temperature; Relative humidity; Maximum vibration; Maximum shock

Dell EMC PowerVault MD3820i
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 10. Power (continued)
NOTE: Heat dissipation is calculated using the
power supply wattage rating. The heat
dissipation values are for the entire system
which includes chassis and two controllers.
Voltage
NOTE: This system is also designed to be
connected to IT power systems with a phase to
phase voltage not exceeding 230 V.
100220 V AC, (8.6 A-4.3 A)
Battery 6.6 V DC, 1100 mAh, 7.26 W Lithium ion battery
Table 11. Environmental
NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/
environmental_datasheets.
Temperature
Operating Continuous operation: 10 °C to 35 °C (50 °F to 95 °F) at 20% to
80% relative humidity (RH), with 26 °C maximum dew point. De-
rate maximum allowable dry bulb temperature at 1 °C/300 m (1 °F
per 550 ft) above 900 m (2952.75 ft).
NOTE: For information on supported expanded operating
temperature range and configurations, see the Owner's Manual
at dell.com/powervaultmanuals.
Storage 40 °C to 65 °C (40 °F to 149 °F) with a maximum temperature
gradation of 20 °C per hour
Relative humidity
Operating 10% to 80% (noncondensing) with maximum humidity gradation of
10% per hour
Storage 5% to 95% at a maximum wet bulb temperature of 33 °C (91 °F)
Maximum vibration
Operating 0.26 G
rms
at 5 Hz to 350 Hz in operational orientation
Storage 1.88 G
rms
at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Maximum shock
Operating
One shock pulse in the positive z axis of the system at 31 G for 2.6
ms in the operational orientation
Storage Six consecutively executed shock pulses in the positive and
negative x, y, and z axes (one pulse on each side of the system) at
71 G for up to 2 ms
Altitude
Operating Maximum 3000 m (9842.5 ft)
NOTE: For altitudes above 2950 ft, the maximum operating
temperature is derated 1.8 ºF/1000 ft.
Storage Maximum 12192 m ( 40,000 ft)
Airborne contaminant level
Class G1 as defined by ISA-S71.04-1985
Table 11. Environmental
Technical Specifications 37