PS6000 Hardware Maintenance Maintaining Power Supply Modules
4–4
To install a power supply and cooling module in an array:
1. Attach an electrostatic wrist strap, as described in Using an Electrostatic Wrist
Strap on page 1-5.
2. See Figure 4-2. Squeeze the latches inward ( ) to release the handle and then
rotate the handle upward ( ).
3. Hold the handle and slide the module into the slot, until you feel resistance.
See Figure 4-3.
Figure 4-4: Installing a Power Supply and Cooling Module
4. Rotate the handle downward until it engages with the latches and the module
is completely inserted. See Figure 4-2.
5. Attach the power cable to the module. If your PS Series array was shipped
with a power cable, use this cable to meet safety requirements.
6. Use the cable strain relief to secure the power cable to the array, as shown in
Figure 4-5.