Upgrading PowerConnect Switches from Version 2.x.x.x or 3.x.x.x or 
4.x.x.x or 5.x.x.x to 5.1.9.3 Firmware
 
 
    Page 15     
2.  Download the 5.1.9.3 firmware from a TFTP server. 
console#copy tftp://10.10.10.200/PCM6220v5.1.9.3.stk image 
Transfer Mode.................................. TFTP 
Server IP Address.............................. 10.10.10.200 
Source File Path............................... / 
Source Filename................................ PCM6220v5.1.9.3.stk 
Data Type...................................... Code 
Destination Filename........................... image 
 
Management access will be blocked for the duration of the transfer 
Are you sure you want to start? (y/n) y 
 
TFTP code transfer starting 
11517952 bytes transferred     
Verifying CRC of file in Flash File System 
Unpacking the image file. 
Distributing the code to the members of the stack! 
File transfer operation completed successfully. 
 
 
console#show version 
Image Descriptions  
 
 image1 : default image  
 image2 :   
 
 Images currently available on Flash  
-------------------------------------------------------------------- 
 unit      image1      image2     current-active        next-active  
--------------------------------------------------------------------  
 
    1     5.1.9.3      2.2.0.3          image2             image2 
 
3.  Activate the 5.1.9.3 firmware  
console#boot system image1 
Activating image image1 .. 
 
4.  Update the boot code and reboot the switch. 
console#update bootcode 
Update bootcode and reset (Y/N)?y 
Updating boot code ...  
BootCode from image1 
 
..........................................................................................
..........................................................................................
..........................................................................................
..........................................................................................
..........................................................................................
..........................................................................................
..........................................................................................
..........................................................................................
..........................................................................................
..........................................................................................
..........................................................................................
..................................BCM56314 DEV REV ID = 0001b314 
 
a.  If using the serial port to update the firmware, the following output will be observed. If logged in 
via telnet or SSH, rebooting the switch will close the connection. Rebooting may take several 
minutes to complete and the switch may reboot itself autonomously during the upgrade procedure.