3-14 Dell PowerEdge 4300 Systems Installation and Troubleshooting Guide
)DQVHQVRU
GHWHFWHGDIDLOXUH
A failure of one or more
fans was detected by the
thermal-monitoring facil-
ity in the specified server.
If possible, the chassis
number and fan number
are provided.
Check for a possible
blockage of or in-
adequate ventilation
around the fan. If the fan
is not blocked and venti-
lation is adequate, check
fan connections. If the
problem is still not
resolved, see Chapter 11,
“Getting Help,” for
instructions on obtaining
technical assistance.
)DQVHQVRUZDUQLQJ
GHWHFWHG
A fan sensor reading on
the specified server has
exceeded the user-
settable warning
thresholds. If possible,
the chassis number and
fan number are provided.
Check for a possible
blockage of or in-
adequate ventilation
around the fan. If the fan
is not blocked and venti-
lation is adequate, check
fan connections. If the
problem is still not
resolved, see Chapter 11,
“Getting Help,” for
instructions on obtaining
technical assistance.
(&&PHPRU\IDXOW An ECC error has
occurred in system
memory.
Run the appropriate
memory test(s) from the
Dell Diagnostics. See
Chapter 5, “Running the
Dell Diagnostics,”
for
more information.
7DEOH'HOO2SHQ0DQDJH+,3$SSOLFDWLRQ$OHUW/RJ
0HVVDJHVFRQWLQXHG
0HVVDJH &DXVH &RUUHFWLYH$FWLRQ
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviations and
acronyms list that precedes the Index.