Installing System Components 125
11
Replace the 
cooling shroud
. See "Installing the Cooling Shroud" on 
page 102.
12
Close the system. See "Closing the System" on page 79.
13
Reconnect the system to its electrical outlet and turn the system on, 
including any attached peripherals.
14
Press <F2> to enter the System Setup program, and check that the processor 
information
 
matches the new system configuration. See "Entering the 
System Setup Program" on page 54.
15
Run the system diagnostics to verify that the new processor 
operates correctly. 
See "Running the Embedded System Diagnostics" on page 162 for 
information about running the diagnostics.
Power Supplies
Your system supports the following power supply modules:
• 350 W (non-redundant power supply)
• 400 W (redundant power supply)
If two power supplies are installed, the second power supply provides 
hot-swappable, power redundancy. In redundant mode, the system distributes 
the power load across both power supplies to maximize efficiency. When a 
power supply is removed with the system powered on, the full power load is 
picked up by the remaining power supply.
Removing a Redundant Power Supply
 CAUTION: Many repairs may only be done by a certified service technician. You 
should only perform troubleshooting and simple repairs as authorized in your 
product documentation, or as directed by the online or telephone service and 
support team. Damage due to servicing that is not authorized by Dell is not covered 
by your warranty. Read and follow the safety instructions that came with the 
product.
 
CAUTION: The system requires one power supply for normal operation. On 
power-redundant systems, remove and replace only one power supply at a time in 
a system that is powered on.
1
Disconnect the power cable from the power source.
R310HOM.book  Page 125  Thursday, March 4, 2010  1:03 AM