21 PowerEdge T620 Technical Guide
With single-wide GPU cards, the PERC H710, H710P, or H810 cannot occupy slots 1 or 3 (PERC
cards have batteries that would overheat if located beside a GPU card)
With two processors installed, four GPU cards are supported, with the restrictions:
Slots 2, 4, 5, and 7 are available
Since double-wide GPU cards occupy two slots, slots 1, 3, and 6 are not available
RAID cards cannot be installed with four double-wide GPU cards
With single-wide GPU cards, the PERC H710, H710P, or H810 cannot occupy slots 1, 3, or 6
(PERCs have batteries that would overheat if located beside a GPU card)
With PCIe SSDs, two GPU cards can occupy slots 5 and 7. Slot 2 is for a PCIe SSD expender card and
slot 4 cannot support a GPU card because of thermal restrictions.
Operating system support for GPUs
Some operating systems have not been validated to support GPUs. See Table 23 and Table 24 for
more information on operating system support of GPUs.
Chipset
The Intel C602 chipset is implemented on the PowerEdge T620. For more information, visit
Intel.com.