74 Appendix—Manual Configuration of iSCSI
Step 8: (Optional) Set Up In-Band Management
Out-of-band management (see "Step 1: Discover the Storage Array (Out-of-
band Management Only)" on page 56) is the recommended method for
managing the storage array. However, to optionally set up in-band
management, use the steps shown below.
The default iSCSI host port IPv4 addresses are shown below for reference:
Controller 0, Port 0: IP: 192.168.130.101 Controller 0, Port 1: IP:
192.168.131.101
Controller 0, Port 0: IP: 192.168.132.101 Controller 0, Port 1: IP:
192.168.133.101
Controller 1, Port 0: IP: 192.168.130.102 Controller 1, Port 1: IP:
192.168.131.102
Controller 1, Port 0: IP: 192.168.132.102 Controller 1, Port 1: IP:
192.168.133.102
NOTE: The management station you are using must be configured for network
communication to the same IP subnet as the PowerVault MD32xxi host ports.
1
Establish an iSCSI session to the PowerVault MD3200i RAID storage array.
2
Restart the
SMagent
service.
3
Launch MDSM.
If this is the first storage array to be set up for management, the
Add New
Storage Array
window is displayed. Otherwise, click
New
.
4
Select
Manual
and click
OK
.
5
Select In-band management and enter the host server name(s) or IP
address(es) of the host server that is running the PowerVault MD Storage
Manager software.
6
Click
Add
.
In-band management should now be successfully configured.