EasyManua.ls Logo

Dell POWERVAULT MD3600F - SAN-Attached Cabling

Dell POWERVAULT MD3600F
22 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring Fibre Channel 17
Figure 7. Four Host Servers With Single-Port HBAs Connected to a Dual-Controller
(Duplex) Storage Array Using Cluster Cabling
Figure 7 shows a four-cluster node connected to two RAID controller
modules. Since each cluster node has redundant paths, loss of a single path
still allows access to the storage array through the alternate path.
SAN-Attached Cabling
SAN-attached cabling configurations provide the highest level of redundancy
and alternate-path connectivity between the host server and storage array. A
SAN configuration using a Fibre Channel compatible switch fabric allows you
to establish multiple redundant paths to data on the storage array.
NOTE: A SAN configuration using a supported Fibre Channel switch hardware is
required if the Remote Replication premium feature is activated on the storage
array. Remote Replication is not supported in a direct-attached configuration. For
specific cabling requirements for Remote Replication, see "Remote Replication
Cabling Example" on page 19.