10 Getting Started With Your System
Operating
10% to 80% (noncondensing) with 29°C
(84.2°F) maximum dew point
Storage
5% to 95% (noncondensing) with 33°C
(91°F) maximum dew point
Maximum vibration
Operating
0.21 G at 5–500 Hz for 15 min
Storage
1.04 G at 2–200 Hz for 15 min
Maximum shock
Operating
Half-sine shock 5 G +/- 5% with a pulse
duration of 10 ms +/- 10% in operational
orientations only
Storage
Half-sine shock 30 G +/- 5% with a pulse
duration of 10 ms +/- 10% (all sides)
Altitude
Operating
0 to 3,048 m (0 to 10,000 ft)
NOTE: For altitudes above 915 m
(3,000 ft), the maximum operating
temperature is derated
1ºC per 300m (1ºF
per 547 ft)
Storage
–300 to 12,192 m (–1000 to 40,000 ft)
Airborne Contaminant Level
Class
G1 or lower as defined by ISA-S71.04-
1985
Environmental (continued)