GAS TAPS
Regular lubrication of the gas taps must only be performed by Authorized
person.
If the gas taps are not working properly, call our Customer Service Centre to
obtain the nearest Authorized Delonghi Service Agent.
CORRECT POSITIONING OF THE BURNERS
It is very important to check that spreader “F” and cap “C” of the burner (see
Figures 16 and 17) are perfectly in place because if they move out of place
serious problems could arise.
Make sure that electrode "S" (Fig. 16) is kept clean so that the sparks always
strike.
Make sure that probe “T” (fig. 16) next to each burner is kept clean to ensure
correct operation of the safety valves.
Both the probe and ignition plug must be very carefully cleaned.
Note: To avoid damage to the electric ignition do not use it when the
burners are not in place.
Figure 16
Figure 17
S
T
F
C