22
FILL BEANS CONTAINER The coee beans have run out. Fill the beans container (A7) (g. 12).
The pre-ground coee funnel (A6) is clogged. Empty the funnel with the help of the brush
(C5) as described in section “13.8 Cleaning the
pre-ground coee funnel”.
INSERT INFUSER ASSEMBLY The infuser (A12) has not been replaced after
cleaning.
Insert the infuser as described in section ““13.9
Cleaning the infuser”.
INSERT TANK The tank (A10) is not correctly in place. Insert the tank correctly and press as far as it
will go (page 3B).
GENERAL ALARM The inside of the appliance is very dirty. Clean the inside of the appliance thoroughly,
as described in section “13. Cleaning”. If the
message is still displayed after cleaning, con-
tact a service centre.
REPLACE FILTER The water softener lter (C4) is exhausted. Replace the lter or remove it as described in
the "Water softener lter" section.
SET DIAL TO CLEAN Milk has been delivered recently and the tubes
inside the milk container (D) must be cleaned.
Turn the froth adjustment dial (D1) to the
CLEAN position.
INSERT WATER SPOUT The hot water spout (C6) is not inserted or is
inserted incorrectly.
Insert water spout as far as it will go.
INSERT MILK CONTAINER The milk container (D) is not inserted correctly. Insert the milk container (g. 20) as far as it
will go.
WATER CIRCUIT EMPTY FILL
WATER CIRCUIT
HOT WATER
Conrm?
The water circuit is empty.
Press (B9) to deliver water from the hot
water spout (C6) until it ows out normally. If
the problem persists, make sure the water tank
(A10) is fully inserted.