13
en
TROUBLESHOOTING
NOTE:
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE
TURNING THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. (After the unit has been on its side, oil needs to return to the
compressor to ensure proper function. Without allowing the unit this time (6-24 hours) The unit may function for only a short time,
and then the compressor will break down from lack of oil.
PROBLEM CAUSE REMEDY
The air
conditioning unit does not start.
• No electricity.
• It is not plugged into the electrical
receptacle.
• The safety device of the plug has
tripped.
• Wait.
• Plug into the electrical receptacle.
• Reset the safety device, if problem
persists contact our toll free
customer service.
The air
conditioning unit works for a short
time only.
• The air exhaust hose has a constric-
tion.
• The air exhaust hose is blocked.
• There are tight bends in the air
exhaust hose.
• Position the exhaust hose correctly.
• Check there are no obstacles that
obstruct the air discharge.
• Eliminate the tight bends.
The air
conditioner works, but does not
cool the room.
• Window open.
• The exhaust hose is detached.
• Air lter clogged.
• Close the window.
• Connect the exhaust hose.
• Clean or replace the lter.
Unpleasant smell in the room • Air purifying lter clogged • Clean or replace the lters.
The air conditioner does not
operate for about 3 minutes after
turning it on
• The safety device has tripped • Wait for three minutes.
The alarm light (L) comes on
• The tank inside the appliance is full. • Empty the tank (see “End of season
operations” ).