EasyManua.ls Logo

Delta Electronics ASDA-A2 Series - Page 176

Delta Electronics ASDA-A2 Series
583 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6 Control Modes of Operation
Relevant parameters:
P2 - 04
KVP Proportional Speed Loop Gain Address: 0208H, 0209H
Default: 500 Related Section:
Applicable Control Mode: ALL Section 6.3.6
Unit: rad/s
Range: 0 ~ 8191
Data Size: 16-bit
Display Format: Decimal
Settings:
This parameter is used to set the speed loop gain. When the value of proportional
speed loop gain is increased, it can expedite speed loop response. However, if the
setting value is over high, it may generate vibration or noise.
P2 - 06
KVI Speed Integral Compensation Address: 020CH, 020DH
Default: 100 Related Section:
Applicable Control Mode: ALL Section 6.3.6
Unit: rad/s
Range: 0 ~ 1023
Data Size: 16-bit
Display Format: Decimal
Settings:
This parameter is used to set the integral time of speed loop. When the value of
speed integral compensation is increased, it can improve the speed response ability
and decrease the speed control deviation. However, if the setting value is over high,
it may generate vibration or noise.
P2 - 07
KVF Speed Feed Forward Gain Address: 020EH, 020FH
Default: 0 Related Section:
Applicable Control Mode: ALL Section 6.3.6
Unit: %
Range: 0 ~ 100
Data Size: 16-bit
Display Format: Decimal
Settings:
This parameter is used to set the feed forward gain when executing speed control
command.
Revision January 2011 6-33
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com

Related product manuals