Chapter 6 Control Modes of Operation
Settings of P2-47
Current Value Desired Value Function
0 1
Clear the setting value of P2-43 ~ P2-46 and enable
auto resonance suppression function.
0 2
Clear the setting value of P2-43 ~ P2-46 and enable
auto resonance suppression function.
1 0
Save the setting value of P2-43 ~ P2-46 and disable
auto resonance suppression function.
1 1
Clear the setting value of P2-43 ~ P2-46 and enable
auto resonance suppression function.
1 2
Do not clear the setting value of P2-43 ~ P2-46 and
enable auto resonance suppression function
continuously.
2 0
Save the setting value of P2-43 ~ P2-46 and disable
auto resonance suppression function.
2 1
Clear the setting value of P2-43 ~ P2-46 and enable
auto resonance suppression function.
2 2
Do not clear the setting value of P2-43 ~ P2-46 and
enable auto resonance suppression function
continuously.
Revision January 2011 6-41