Chapter 8 Servo Parameters
Revision January 2011 8-39
P0 - 21 CM5A Status Monitor Selection 5 Address: 002AH, 002BH
Default: 0 Related Section: N/A
Applicable Control Mode: ALL
Unit: N/A
Range: 0 ~ 127
Data Size: 16-bit
Display Format: Decimal
Settings:
This parameter is used to determine the drive status found in P0-02. The selected drive
status will be displayed by P0-13. Refer to P0-17 for explanation.
P0 - 22 Reserved (Do Not Use)
P0 - 23 Reserved (Do Not Use)
P0 - 24 Reserved (Do Not Use)
P0 - 25 MAP1 Mapping Parameter 1 Address: 0032H, 0033H
Default: N/A Related Section:
Applicable Control Mode: ALL Section 4.3.5
Unit: N/A
Range: determined by the parameter specified by P0-35
Data Size: 32-bit
Display Format: Hexadecimal
Settings:
The parameters from P0-25 to P0-32 are used to read and write the values of the
parameters those communication addresses are not consecutive. The users can set P0-
35 ~ P0-42 as the desired read and write mapping parameter numbers through
communication setting or the keypad. When reading or writing P0-25 ~ P0-32, the read
or write values are equivalent to the values of the parameters specified by P0-35 ~ P0-
42, and vise versa. Refer to P0-35 for explanation.