Chapter 8 Servo Parameters
Revision January 2011 8-185
P6 - 68
PDEF34 Definition of Path 34 Address: 0688H, 0689H
Default: 0x00000000 Related Section:
Applicable Control Mode: PR Section 7.10
Unit: N/A
Range: 0x00000000 ~ 0xFFFFFFFF
Data Size: 32-bit
Display Format: Decimal
Settings:
Refer to P6-02 for explanation.
P6 - 69
PDAT34 Data of Path 34 Address: 068AH, 068BH
Default: 0 Related Section:
Applicable Control Mode: PR Section 7.10
Unit: N/A
Range: -2147483648 ~ +2147483647
Data Size: 32-bit
Display Format: Decimal
Settings:
Refer to P6-03 for explanation.
P6 - 70
PDEF35 Definition of Path 35 Address: 068CH, 068DH
Default: 0x00000000 Related Section:
Applicable Control Mode: PR Section 7.10
Unit: N/A
Range: 0x00000000 ~ 0xFFFFFFFF
Data Size: 32-bit
Display Format: Decimal
Settings:
Refer to P6-02 for explanation.
P6 - 71
PDAT35 Data of Path 35 Address: 068EH, 068FH
Default: 0 Related Section:
Applicable Control Mode: PR Section 7.10
Unit: N/A
Range: -2147483648 ~ +2147483647
Data Size: 32-bit