What to do if Delta Electronics RT-1K signals DC-DC Fault?
- DDesiree CunninghamSep 12, 2025
If your Delta Electronics UPS indicates a DC-DC fault, it means that the UPS has abnormalities. Contact service personnel.

What to do if Delta Electronics RT-1K signals DC-DC Fault?
If your Delta Electronics UPS indicates a DC-DC fault, it means that the UPS has abnormalities. Contact service personnel.
What to do if my Delta Electronics RT-1K indicates Battery Low Shutdown?
If your Delta Electronics UPS is shutting down due to a low battery, it's likely because it switched to battery mode due to an AC power issue, and the battery is nearly depleted. First, check the main AC power source and the power cord. If the problem persists, contact service personnel.
What to do if Delta Electronics UPS reports Fan Fault?
If your Delta Electronics UPS reports a fan fault, it means the fan is either damaged or obstructed. First, check if any foreign objects are stuck in the fan and remove them. If the problem continues, contact service personnel.
What to do if Delta Electronics RT-1K UPS shows Over Temperature?
If your Delta Electronics UPS displays an over temperature warning, it indicates that the internal temperature is too high. You should: 1. Ensure the UPS ventilation is unobstructed. 2. Reduce the connected loads. 3. Verify that the fan is functioning correctly.
What to do if my Delta Electronics RT-1K UPS shows O/P Short?
If your Delta Electronics UPS indicates an output short circuit, it means there's likely a short in the connected equipment. First, check the output for any short-circuit issues. If the problem persists, contact service personnel.
What to do if Delta Electronics UPS signals Battery Missing?
If your Delta Electronics UPS indicates that the battery is missing, it could be due to incorrect battery wiring or loose connections. You should connect the battery cables properly. If the problem persists, contact service personnel.
What to do if Delta Electronics RT-1K signals 'Battery Save' Shutdown?
If your Delta Electronics UPS indicates ''Battery Save' shutdown', it means the function is enabled because the total load is too small or there is no load connected, after running in battery mode for 30 minutes. Contact service personnel.
What to do if Delta Electronics RT-1K signals Abnormal Output/ Inverter Voltage?
If your Delta Electronics UPS indicates an abnormal output or inverter voltage, it means that the UPS has abnormalities. Contact service personnel.
What to do if Delta Electronics UPS signals Inverter Fault?
If your Delta Electronics UPS indicates an inverter fault, it means that the UPS has abnormalities. Contact service personnel.
What to do if Delta Electronics UPS signals Charger Fault?
If your Delta Electronics UPS indicates a charger fault, it means the charger is damaged. Contact service personnel.
| Brand | Delta Electronics |
|---|---|
| Model | RT-1K |
| Category | UPS |
| Language | English |
Covers intended use, handling, placement, general warnings, usage, and battery precautions.
Overview of the UPS operation panel components (LEDs, LCD, buttons).
Explains icons, 7-segment, and 16-segment displays on the LCD.
Lists error codes, meanings, and possible causes for troubleshooting.
Shows rear panel layout and details functions of ports and connectors.
Step-by-step guide for rack-mounting the UPS and external battery pack.
Step-by-step guide for tower-mounting the UPS and external battery pack.
Steps for connecting the UPS to the AC utility power.
Overview of settings configurable in Setup mode and setup procedures.
How to perform manual and automatic battery tests.
Critical warnings and precautions before replacing internal batteries.
Lists error codes, meanings, possible causes, and solutions.
Detailed specifications for RT-1K, RT-2K, RT-3K models and external battery packs.
Seller warranty terms, exclusions, and maintenance service details.