Chapter 4 Parameter Settings|DD Series
4-9
03 Feedback Parameters This parameter can be set during
operation.
Paramete
r
Explanation
Settings
Factory
Setting
VF
VFP
SVC
FOC
FOC
03.00
Encoder (PG) Signal Type
0: No function
1: ABZ
7: PWM pulse
7
03.01
Encoder pulse
1~25000 256
03.02
Encoder Input Type Setting
0: Disable
1: Phase A leads in a forward run
command and phase B leads in a
reverse run command
2: Phase B leads in a forward run
command and phase A leads in a
reverse run command
3: Phase A is a pulse input and phase B
is a direction input. (low input=reverse
direction, high input=forward direction)
4: Phase A is a pulse input and phase B
is a direction input. (low input=forward
direction, high input=reverse direction)
5: Single-phase input
1
03.03
Encoder Feedback Fault
Treatment (PGF1, PGF2)
0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and stop operation
2
03.04
Detection Time for Encoder
Feedback Fault
0.0~10.0sec 1.0
03.05
Encoder Stall Level (PGF3)
0~120% (0:Disable) 115
03-06
Encoder Stall Detection
Time
0.02.0sec
0.1
03.07
Encoder Slip Range
(PGF4)
0~50% (0:Disable) 50
03.08
Encoder Slip Detection
Time
0.010.0sec
0.5
03.09
Encoder Stall and Slip Erro
r
Treatment
0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and coast to stop
2
03.10
Door Width Auto-tuning
Frequency
0.10~120.00Hz 5.0
03.11
Door Width Auto-tuning
0: Disable
1: Enable
0
03.12
Door Width Pulse (Unit:1)
1~9999 8800
03.13
Door Width Pulse
(Unit:10000)
0~9999 (Unit:10000) 0