9.2 Charger Error Codes
Code Description Solution
E-0-0-1
E-0-2-1
Battery high voltage Check the battery voltage and cable connections. Check battery size and
condition. This error will automatically clear once the condition has been
corrected.
E-0-0-2
E-0-2-2
Battery low voltage Check the battery voltage and cable connections. Check battery size and
condition. This error will automatically clear once the condition has been
corrected.
E-0-0-3 Charge timeout caused
by battery pack not
reaching required
voltage within safe
time limit.
Possible causes: Charger output reduced due to high temperatures, poor battery
health, very deeply discharged battery and /or poorly connected battery.
Possible solutions: Operate at lower ambient temperature. Replace battery pack.
Check DC connections. This error will automatically clear once the charger is
reset by cycling DC.
E-0-0-4 Battery could not meet
minimum voltage
Check for shorted or damaged cells. Replace battery pack. Check DC
connections. This error will automatically clear once the charger is reset by
cycling DC.
E-0-0-5 Charger temperature
limit exceeded
Ensure sufficient cooling air flow and reset charger (disconnect DC or AC for 10
minutes then reconnect). This error will automatically clear once the condition
has been corrected.
E-0-0-6 Low AC voltage error Connect charger to an AC source that provides stable AC between 85 - 270
VAC / 45-65 Hz. This error will automatically clear once the condition has been
corrected.
E-0-0-7 Battery amp hour limit
exceeded
Possible causes include poor battery health, very deeply discharged battery,
poorly connected battery, and / or high parasitic loads on battery while
charging. Possible solutions: Replace battery pack. Check DC connections.
Disconnect parasitic loads. This error will automatically clear once the charger is
reset by cycling DC.
E-0-0-8 Battery temperature is
out of range
Possible battery temperature sensor error. Check temperature sensor and
connections. Reset charger. This error will automatically clear once the condition
has been corrected.
E-0-1-2 Reverse polarity error Battery is connected to the charger incorrectly. Check the battery connections.
This error will automatically clear once the condition has been corrected.
E-0-1-6
E-0-1-8
E-0-2-6
USB operation failed Software upgrade failure or script operation failure. Ensure the USB flash drive is
properly formatted and retry inserting the USB flash drive into the charger.
E-0-2-3 High AC voltage error
(>270VAC)
Connect charger to an AC source that provides stable AC between 85 - 270
VAC / 45-65 Hz. This error will automatically clear once the condition has been
corrected.
E-0-2-4 Charger failed to
initialize
The charger has failed to turn on properly. Disconnect AC input and battery for
30 seconds before retrying.
E-0-2-5 Low AC voltage
oscillation error
AC source is unstable. Could be caused by undersized generator and /or severely
undersized input cables. Connect charger to an AC source that provides stable
AC between 85 - 270 VAC / 45-65 Hz. This error will automatically clear once the
condition has been corrected.