DC Output 24 VDC 36 VDC 48 VDC
Nominal DC output voltage 24 V 36 V 48 V
Maximum DC output voltage 36 V 54 V 72 V
Maximum DC output current 27.1 A 18.1 A 13.5 A
Maximum DC output power 650 W 650 W 650 W
Deep discharge recovery
(minimum voltage)
1.2 V 1.8 V 2.4 V
Maximum interlock current 1 A 1 A 1 A
Ripple Voltage ripple < 0.5%p-p Current ripple < 2.5%p-p
Battery type Lead acid (Wet / AGM / GEL), lithium Ion
Reverse polarity Electronic protection with auto-reset
Short circuit Electronic current limit
© 2013 Delta-Q Technologies Corp. All rights reserved.
(DOCUMENT 720-0011 Date: 18/03/2013)
Features
Multi-color LED indicator for AC
source, battery status (<80% /
>80% / completion), charging,
alarm, fault
Numeric display for charge
profile, alarm / fault codes
Field programmable with up to
25 QuiQ
TM
charge profiles
OEM customizable, field
replaceable cable design
AC Input
AC input voltage range 85-270 VAC
Nominal AC input voltage 100-240 VAC
Nominal AC input frequency 50 / 60 Hz
Maximum AC input current 7.5 A
Nominal AC input current 7.3 A @ 100 VAC 6.0 A @ 120 VAC
3.1 A @ 230 VAC 2.9 A @ 240 VAC
Nominal AC power factor >0.99 @ 120 VAC >0.98 @ 230 VAC
Power Conversion Eciency 90.7% at full load
(120 VAC, 48 VDC)
93.5% at full load
(240 VAC, 48 VDC)
Regulatory
Safety Approval pending to UL1564, CSA 107.2, EN 60335-2-29, AS/
NZS60335
Emissions FCC Part 15 / ICES 003 Class A, EN55011
Immunity EN61000-3-2, EN61000-3-3, EN 61000-4-2/-3/-4/-5/-6/-11
Environmental ROHS and REACH compliant
Eciency Meets California Energy Commission (CEC) energy eciency
standards for battery charging systems
Dimensions
252mm
(9.9”)
186mm
(7.3”)
80mm
(3.1”)
IC650 Specifications
Environmental
Operating temperature -40
o
C to +65
o
C (-40
o
F to 149
o
F) Derated at >40
o
C (104
o
F)
Storage temperature -40
o
C to +85
o
C (-40
o
F to 185
o
F)
Ingress Protection IP66 (Complete protection against contact, dust, and powerful water jets) with Delta-Q supplied AC cord
Chemical MIL 810-G, Method 504.1: Withstands exposure to chemicals typically found in application (battery acid, salt,
cleaners, fertilizers, etc.)
Salt Withstands 720 hours (30 days) salt spray test per GMW 3172 with 5% (w/w) salt solution (pH 6.5-7.2) at 35
o
C (95
o
F)
without degradation of performance
Shock / Vibration Infrequent shock: 100g, 11ms half-sine pulse, 3 cycles in each of 3 axes
Repetitive shock (bump): 25g, 11ms, 2400 cycles
Vibration: Random vibration of 4.55g from 10-1000Hz for 8 hours in each of 3 axes, using the sprung mass prole of
GMW 3172
Humidity 0 to 95% non-condensing
Altitude < 15,000 feet derated above 20
o
C