28
Mechanical
Dimensions Charger: 25.2 x 18.6 x 8.0 cm (9.9 x 7.3 x 3.1”)
Shipping carton: 32.5 x 30.5 x 12.0 cm (12.8 x. 12.0 x 4.5”)
Weight Charger: 2.4 kg (5.3 lbs)
Shipping carton: 3.0 kg (6.6 lbs)
AC input connector IEC320 / C14 (requires country-specic cord)
DC output connector M6 threaded fasteners for ring terminals, eld replaceable in the event of cross-threading or other damage
Signal Connector IC650 BASE
IC650 COMM
6.3 mm (1/4”) blade terminals:
C1 - Battery temp. sense ‘-’
C2 - Battery temp. sense ‘+’
C3 - Interlock signal
6.3 mm (1/4”) blade terminals:
C1 - Battery temp. sense ‘-’
C2 - Battery temp. sense ‘+’
C3 - Interlock signal
TE AmpSeal automotive connector (IP67 rated) mates
with TE Connectivity AmpSeal Plug (p/n: 776273): Signals
for CAN bus (isolated); Remote status indicators; Battery
temperature sense; Interlock; Enable / disable; Modbus
Service port Sealed (IP66) USB 2.0 Host Port (Type A) with dust cover
Mounting holes 6.3 mm (1/4”) diameter slots in each corner for safe installation on shelf, wall or bulkhead
Cooling Normal operation in any orientation with passive cooling only
Communications / Signals IC650 BASE IC650 COMM
Battery temperature input Isolated temperature sensor signals (mates with Delta-Q isolated battery temperature sensors)
Charge enable / disable input Not available PWM signal
Interlock signal Standard (Battery positive signal when AC not
present)
NO or NC (selectable) dry contact
0.5 A fast-blow fuse (>100 VDC rated) required
Remote status indicator Not available Tri-color red / yellow / green
CANbus Not available Isolated CAN-H, CAN-L, CAN-GND
CANopen CiA 418: Battery and CiA 419: charger
CANopen CiA 454: Light electrical vehicles (LEV)
Serial communications Not available Modbus RTU
Operation
Status indicators AC present, charging status (low state-of-charge, high state-of-charge, complete), alarm, fault, USB activity
Numeric display Displays selected charging prole, alarm and / or fault codes
Long-term storage mode Automatic restart to maintain battery state-of-charge and prevent sulphation or freezing
Power source Charge control circuitry powered from AC input. Backup power provided by battery if AC not present.
Standby AC power consumption 2.40 W
Quiescent DC current
(connected to battery only)
24 VDC 36 VDC 48 VDC
27 mA (0.65 W) 18 mA (0.65 W) 15 mA (0.72 W)
USB Host Port
Required equipment Standard USB ash drive with FAT formatting
Charge Tracking Data
Points
VAC, IAC, VDC, IDC, temperature (battery & charger) Ahr returned, charge duration, end of charge voltage, fault /
error codes logged
Software Update Allows updating of software using USB ash drive, replacing software and / or charge proles