AS Series Module Manual
11-90
11
11. Click menu Network >> Download to download AS01DNET (RTU) configuration to the master.
The input mapping address D26005~D26018 and output mapping address D26105~D26114 are for AS01DNET
(RTU). The start input address D26005 and start output address D26105 are respectively used as the status word
and control word of AS01DNET (RTU). The parameter mappings of all modules connected to AS01DNET (RTU) are
displayed below.
I/O Module
Input
Output
AS16AP
D26006
D26106-
AS04DA
Status
D26007~D26008
Channel 1 output value
D26107~D26108
Channel 2 output value
-
D26109~D26110
Channel 3 output value
-
D26111~D26112
Channel 4 output value
-
D26113~D26114
AS04AD
Status D2609~D26010
Channel 1 input value D26011~D26012
Channel 2 input value
D26013~D26014
Channel 3 input value
D26015~D26016
Channel 4 input value
D26017~D26018