INSTALLATION AND OPERATING INSTRUCTIONS
CEILING/WALL VENTILATION FAN
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INFORMATION
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Make sure that the electric service supply voltage is AC
120V, 60Hz.
2. Follow all local electrical and safety codes, as well as
the National Electrical Code (NEC) and the Occupation
al Safety and Healthy Act (OSHAct).
3. Always disconnect the power source before working
on or near the ventilating fan, motor or junction box.
4. Protect the power cord from sharp edges, oil, grease,
hot surfaces, chemicals or other objects.
5. Do not kink the power cord.
6. Do not install the unit where ducts are congured as
shown in Fig. A.
7. Provide suction parts with proper ventilation.
8. This unit is UL listed for use over a bathtub or shower
when installed in a GFCI protected branch circuit.
1. For General Ventilating Use Only. Do Not Use To
Exhaust Hazardous Or Explosive Materials And Vapors.
2. Not for use in cooking area. (Fig. B)
3. This product must properly connect to the grounding
conductor of the supply circuit.
4. To reduce the risk of injury to persons, install the fan at
least 8.2 feet (2.5m) above the oor.
1. Single Speed Model: ITG80
Single speed control mode: Turn the power switch to
operate ON/OFF.
1. Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact the
manufacturer.
2. Before servicing or cleaning the unit, switch power o
at service panel and lock the service disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualied person(s) in accordance with all applicable
codes and standards, including re-rated construction.
4. Sucient air is needed for proper combustion and
exhausting of gases through the ue (chimney) of fuel
burning equipment to prevent back drafting. Follow
the heating equipment manufacturer’s guideline and
safety standards such as those published by the National
Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it
must be marked as appropriate for the application and
be connected to a GFCI (Ground Fault Circuit
Interrupter) – protected branch circuit.
8. Do not use this unit with any other solid-state control
device. Solid-state controls devices may cause harmonic
distortion, which can cause a motor humming noise.
9. NEVER place a switch where it can be reached from a
tub or shower.
10. Not to be installed in a ceiling thermally insulated to a
value greater than R40. (This is required for installation
in Canada only).
CAUTION
SUPPLIED ACCESSORIES
Part name
Appearance Quantity
Grille
1
Fan
1
Housing
1
4” Duct
1
Screw
(M4x12)
3
45
o
Cooking area
45
o
Do not install above or
inside this area
Cooking
Equipment
floor
Fig. B
DIMENSIONS
SPECIFICATIONS
Note: Design and specications are subject to change
without notice.
Operation
MAINTENANCE WARNING:
Disconnect the power source before working on the
unit. Routine maintenance must be done every year.
CAUTION:
1. Never use gasoline, benzene, thinner or any
other such chemicals for cleaning the
ventilating fan.
2. Do not allow water to enter the motor.
3. Do not soak resin parts in water over 60°C (140
o
F).
CLEANING
1. Pull down the spring to remove the grille.
2. Wash and clean the grille. (Use non-abrasive
kitchen detergent and wipe dry with a new
cloth.)
3. Remove dust and dirt from the ventilating fan
using a vacuum cleaner.
4. Using a cloth dampened with kitchen detergent,
remove any dirt from the ventilating fan. Wipe
dry with a new cloth.
5. Replace the grille.
Model No.
Voltage
(V)
Frequency
(Hz)
Power
(W)
Air Flow
@ 0.1SP
(CFM)
Weight
(lb.)
Note
ITG80
120
60 12
80
4.0
Single
Speed
Turning angle too large Duct shrink
Too many elbows
Elbow near the body
Body
Fig. A
Page 1.
MODEL: ITG80
Question and Answer IconNeed help?

Do you have a question about the Delta BreezIntegrity ITG80 and is the answer not in the manual?

Summary

Ceiling and Wall Ventilation Fan Instructions

General Safety Information

General safety precautions for electrical installation and unit usage.

Cautions for Use

Cautions regarding use with hazardous materials, cooking areas, and grounding.

Risk Reduction Warnings

Critical warnings about fire, shock, injury, proper installation, and maintenance.

Technical Specifications

Technical specifications of the ventilation fan model ITG80.

Fan Operation

Instructions on how to operate the single-speed ventilation fan.

Maintenance and Cleaning

Guidance on maintenance, cleaning, and associated warnings.

Supplied Accessories

Lists components included with the ventilation fan unit.

Installation Guide

Unit Preparation and Wiring

Steps for preparing the unit, wiring, and duct connections.

Ceiling Installation Methods

Guidance for new and replacement installations in ceilings.

Final Assembly and Checks

Instructions for plugging in the motor, mounting the grille, and initial checks.

Product Warranty Information

Three Year Limited Warranty

Details of the three-year limited warranty from Delta Electronics.

Warranty Limitations and Exclusions

Terms and conditions that limit the warranty coverage.

Overview

The Delta Breez Integrity ITG80 is a ceiling/wall ventilation fan designed for general ventilating use in residential settings. It is specifically designed to exhaust air and maintain proper ventilation, contributing to a healthier indoor environment. The fan is UL listed for use over a bathtub or shower when installed in a GFCI protected branch circuit, making it suitable for high-humidity areas. However, it is explicitly stated that the fan is not to be used in cooking areas or to exhaust hazardous or explosive materials and vapors. It is also not recommended for installation in a ceiling thermally insulated to a value greater than R40 (required for installation in Canada only).

Function Description:

The primary function of the ITG80 is to move air from inside a room to the outdoors, helping to reduce humidity, odors, and airborne pollutants. It operates as a single-speed fan, controlled by a simple ON/OFF power switch. The fan is designed for ducted installation, requiring connection to a 4-inch circular duct that vents to the outdoors. Proper ducting is crucial for optimal performance, with recommendations for the shortest, straightest duct routing possible to minimize airflow resistance, noise, and energy consumption. Insulation around the ducts is also suggested to reduce energy loss and inhibit mold growth.

Important Technical Specifications:

  • Model Number: ITG80
  • Voltage: 120V AC
  • Frequency: 60Hz
  • Power Consumption: 12W
  • Air Flow: 80 CFM (Cubic Feet per Minute) at 0.1 SP (Static Pressure)
  • Weight: 4.0 lbs
  • Speed: Single Speed
  • Installation Dimensions: 7.5 x 7.25 inches
  • Duct Size: 4-inch circular duct
  • Installation Height: Must be installed at least 8.2 feet (2.5m) above the floor.

Usage Features:

  • Single-Speed Operation: The ITG80 offers straightforward operation with a single speed setting, controlled by a standard ON/OFF wall switch.
  • Versatile Installation: It can be installed in both ceilings and walls, providing flexibility for different room layouts. The manual provides detailed instructions for both new installations (prior to finishing the ceiling) and replacement installations in existing ceilings.
  • Bathroom/Shower Compatibility: The fan's UL listing for use over bathtubs or showers (when GFCI protected) makes it a suitable choice for ventilating bathrooms and preventing moisture buildup.
  • Ducting Recommendations: The manual emphasizes the importance of proper ducting for optimal performance. It recommends using a 4-inch circular duct and avoiding configurations with too many elbows or sharp turns, as these can significantly reduce airflow and increase noise. A short piece of flexible duct is suggested to help with alignment and absorb sound.
  • Safety Guidelines: The device includes comprehensive safety guidelines, such as disconnecting power before servicing, following local electrical codes, and ensuring proper grounding. It also warns against installing the unit where ducts are configured in a way that restricts airflow or creates excessive back pressure.

Maintenance Features:

  • Routine Maintenance: The manual recommends routine maintenance annually to ensure the fan's longevity and optimal performance.
  • Easy Grille Removal: The grille can be easily removed by pulling down on its springs, simplifying the cleaning process.
  • Cleaning Instructions:
    • The grille should be washed and cleaned with a non-abrasive kitchen detergent and wiped dry with a new cloth.
    • Dust and dirt can be removed from the ventilating fan using a vacuum cleaner.
    • The fan's interior can be cleaned with a cloth dampened with kitchen detergent, followed by wiping dry with a new cloth.
  • Cleaning Precautions:
    • Never use gasoline, benzene, thinner, or other harsh chemicals for cleaning.
    • Do not allow water to enter the motor.
    • Do not soak resin parts in water over 60°C (140°F).
  • Power Disconnection: Users are instructed to disconnect the power source before performing any maintenance work to prevent electrical shock.

Warranty Information:

Delta Electronics Inc. provides a three-year limited warranty to the original consumer purchaser in the USA and Canada, covering defects in material and workmanship. The warranty does not cover labor charges, indirect damages, or issues arising from improper installation, misuse, or neglect. To qualify for warranty service, customers must notify Delta Electronics at the provided address or telephone number.

Delta BreezIntegrity ITG80 Specifications

General IconGeneral
BrandDelta
ModelBreezIntegrity ITG80
CategoryFan
LanguageEnglish

Related product manuals