14
A further description of the equipment features:
(1) Solar Inverter Power Box - This is the inverter section of the assembly. This section is sealed
at the factory and there are no user-serviceable parts inside. All wiring to install the inverter is
done in the wiring box.
(2) Wiring Box Cover - This is the cover for the wiring compartment.
(3) LED indicator - The ve LED lights indicate errors or status as described in section 8.
(4) Mounting Plate - The inverter ships with a mounting plate that allows easily assembly of the
inverter to a wall.
(5) Wiring Box - This is the compartment where all the wiring for the inverter inputs and outputs
plus the RS485 communication are done.
(6) Lockable DC Disconnect - The DC disconnect is lockable per the UL code and allows for the
DC power to be switched o󰀨 to the inverter
(7) Conduit Plugs - There are 5 - 3/4“ conduit openings and 2 - 1/2“ conduit openings. Each
conduit opening comes tted with a conduit plug that should be removed before installing conduit
ttings. Conduit ttings need to be water tight with either NEMA 4, 4X, 6, or 6X rated, and insula-
ted type is preferred.
2.8 Inverter type and safety labels
The type label is shown in gure 7. Di󰀨erent type labels can be found on the models E6-TL-US
and E8-TL-US. The inverter serial number can be found on the type label.
The main caution labels in English and French are on the left side of the inverter.