CEILING/WALL VENTILATION FAN
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INFORMATION
1. Make sure that the electric service supply voltage is
AC 120V, 60Hz.
2. Follow all local electrical and safety codes, as well as
the Nation Electrical Code (NEC) and the Occupation
Safety and Health Act (OSH Act).
3. Always disconnect the power source before working
on or near the ventilating fan, motor or junction box.
4. Protect the power cord from sharp edges, oil, grease,
hot surfaces, chemicals or other objects.
5. Do not kink the power cord
.
6. Do not install the unit where ducts are congured as
shown in Fig. A.
7. Provide suction parts with proper ventilation.
8. This unit is UL listed for use over a bathtub or shower
when installed in a GFCI protected branch circuit.
9. These ventilating fans are intended for residential
usage only.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
Turning angle too large Duct shrink
Too many elbows Elbow near the body
Body
CAUTION
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and vapors.
2. Not for use in cooking areas. (Fig. B)
4
5
Cooking a rea
4
5
Do not install above or
in s ide this are a
C oo k ing
Equip ment
floor
SUPPLIED ACCESSORIES
Fig. A
Fig. B
1. Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact
the manufacturer.
2.
3. Installation work and electrical wiring must be
done by qualied person(s) in accordance with
all applicable codes and standards, including
re -rated construction.
4.
5. When cutting or drilling into walls or ceiling s, do
not damage electrical wiring and other hidden
utilities.
6.
7.
Ducted ventilating fans must always be vented to
the outdoors.
8.
If this unit is to be installed over a tub or shower, it
must be marked as appropriate for the application
and be connected to a GFCI (Ground Fault Circuit
Interrupter) -protected branch circuit.
3.
4.
This product must be properly grounded
Part name Appearance Quantity
Grille
1
Fan
1
Housing
1
Duct
1
Screw
(M4x12)
3
DIMENSIONS
SPECIFICATIONS
Note: Design and specications subject to change
without notice.
OPERATION
1. Single Speed Model: SLM50
2. Single Speed Model: SLM70
Model No.
Voltage
(V)
Frequency
(Hz)
Power
(W)
Air Flow
@ 0.1SP
(CFM)
Weight
(lb.)
Note
SLM50 120 60 6.4 50 3.65
Single
Speed
SLM70 120 60 16 70 3.65
Single
Speed
MAINTENANCE WARNING:
Disconnect the power source before working on the unit.
Routine maintenance must be done every year.
CAUTION:
1. Never use gasoline, benzene, thinner or any other
such chemicals for cleaning the ventilating fan.
2. Do not allow water to enter the motor.
3. Do not soak resin parts in water over 60°C (140°F) .
CLEANING
1. Pull down the spring to remove the grille.
2. Wash and clean the grille. (Use non-abrasive
kitchen de tergent, wipe dry with a new cloth.)
3. Remove dust and dirt from the ventilating fan
using a vacuum cleaner.
4. Using a cloth dampened with kitchen detergent,
remove any dirt from ventilating fan. Wipe dry
with a new cloth.
5. Replace the grille.
Before servicing or cleaning the unit, switch the
power o at the service panel and lock the service
disconnecting means to prevent the power from
being switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag,
to the service panel.
Single speed control mode: Turn the power
switch to operate ON/OFF. The LED indicator will
be green.
Single speed control mode: Turn the power
switch to operate ON/OFF. The LED indicator will
be green.
To reduce the risk of injury to persons, install the
fan at least 7 feet (2.1m) above the oor.
Sucient air is needed for proper combustion and
exhausting of gases through the ue (chimney) of
fuel burning equipment to prevent back drafting.
Follow the heating equipment manufacturer’s
guideline and safety standards such as those
published by the National Fire Protection
Association (NFPA), and the American Society for
Heating Refrigeration and Air Conditioning
Engineers (ASHRAE) and the local code authorities.
Do not use this unit with any other solid-state
control device. Solid-state controls devices may
cause harmonic distortion, which can cause a
motor humming noise.
10.
Not to be installed in a ceiling thermally insulated
to a value greater than R50. (This is required for
installation in Canada only).
9.
NEVER place a switch where it can be reached
from a tub or shower.
INSTALLATION AND OPERATING INSTRUCTIONS
Page 1.
MODELS SLM50 / SLM70
Question and Answer IconNeed help?

Do you have a question about the Delta SLM50 and is the answer not in the manual?

Delta SLM50 Specifications

General IconGeneral
CategoryFan
Dimensions50x50x10 mm
Connector3-Pin
Voltage12 V
ModelDelta SLM50

Summary

General Safety Information and Warnings

Electrical Safety Compliance

Ensure electric service supply is AC 120V, 60Hz and follow all electrical and safety codes.

Power Disconnection Protocol

Always disconnect the power source before working on or near the ventilating fan, motor, or junction box.

Power Cord Handling

Protect the power cord from sharp edges, oil, grease, hot surfaces, and chemicals; do not kink it.

Installation and Usage Restrictions

Do not install where ducts are configured as shown in Fig. A; ensure proper ventilation and GFCI protection.

Specific Warnings and Cautions

Observe warnings regarding unit use, servicing, wiring, air requirements, and avoiding switches near tubs.

Product Operation and Maintenance

Ventilation Fan Operation

Operate SLM50 and SLM70 models via the power switch; LED indicator will be green.

Maintenance Warning

Disconnect power source before any work on the unit; routine maintenance is required annually.

Cleaning Procedures

Clean grille and fan using non-abrasive detergent and vacuum; avoid chemicals and soaking resin parts.

Installation Instructions

Preparation and Wiring

Remove motor plate and wiring cover, follow codes, and connect house power cable using wire nuts.

Ductwork Installation

Insert duct, tape connections securely, and install with a 1°~2° gradient towards the outside.

Mounting the Housing

Install housing between joists or nail to studs/joists, ensuring it is level and perpendicular.

Grille Attachment

Insert mounting springs into slots, push grille against surface, and secure to the body.

Warranty Information

Limited Warranty Coverage

Delta Electronics warrants Breez ventilation fans for three years from original purchase date.

Limitations and Exclusions

Warranty excludes labor costs, misuse, neglect, improper installation, or non-compliance with manual.