EasyManua.ls Logo

Delta VFD1100C43A-HS

Delta VFD1100C43A-HS
814 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 11 Summary of Parameter SettingsC2000-HS
11-44
Pr. Parameter Name Setting Range Default
10-30 Resolver pole pair 1–50 pole pairs 1
10-31 I/F mode, current command 0–150% of motor rated current 40
10-32
PM FOC sensorless speed
estimator bandwidth
0.0–1500.0 Hz 5.0
10-34
PM sensorless speed estimator
low-pass filter gain
0.00–655.35 1.00
10-35 AMR (Kp) gain 0.00–3.00 1.00
10-36 AMR (Ki) gain 0.00–3.00 0.20
10-37 PM sensorless control word 0000–FFFFh 0000h
10-39
Frequency point to switch from
I/F mode to PM sensorless
mode
0.0–1500.0 Hz 20.0
10-40
Frequency point to switch from
PM sensorless mode to V/F
mode
0.0–1500.0 Hz 20.0
10-41
I/F mode, Id current low
pass-filter time
0.0–6.0 sec. 0.2
10-42
Initial angle detection pulse
value
0.0–3.0 1.0
10-43 PG card version 0–655.35
Read
only
10-49 Zero voltage time during start-up 0.000–60.000 sec. 0.000
10-50
Reverse angle limit (Electrical
angle)
0.00–30.00 degree 10.00
10-51 Injection frequency 0–1200 Hz 500
10-52 Injection magnitude 0.0–200.0V 30.0
10-53
PM initial rotor position
detection method
0: Disable
1: Internal 1/4 rated current attracting the rotor to zero
degrees
2: High frequency injection
3: Pulse injection
0
10-54
Magnetic linkage estimator
low-speed gain
10–1000% 100
10-55
Magnetic linkage estimator
high-speed gain
10–1000% 100
10-56 Phase locked loop (PLL) Kp 10–1000% 100
10-57 Phase locked loop (PLL) Ki 10–1000% 100

Table of Contents

Related product manuals