Chapter 11 Summary of Parameter Settings | VFD-ED
Pr. Parameter Name Setting Range Default
VF
31: High torque bias (according to
○ ○
○
○
○
32: Middle torque bias (according to
Pr.07-22)
○ ○
○
○
○
33: Low torque bias (according to Pr.07-
○ ○
○
○
○
38: Disable writing to EEPROM function
39: Torque command direction (0 is
positive direction)
40: Enable drive function
41: Magnetic contactor detection
43: EPS function (Emergency Power
System)
○ ○
○
○
○
45–51: Direct docking mode only
◆
53: Terminal leveling signal for direct
○
○
○
55: Manual emergency deceleration
56: Automatic emergency deceleration
57: Brake torque test action signal
02-09
Digital Input Response
0.001–30.000 sec. 0.005 ○ ○
○
○
○
02-10
Digital Input Operation
Direction
0–65535 0 ○ ○
○
○
○
02-11
Multi-function Output 1:
02-12
Multi-function Output 2:
MRA, MRB, MRC
2: Operation speed reached
3: Desired frequency reached 1 (Pr.02-
25, Pr.02-26)
○ ○
○
○
○
02-13
Multi-function Output 3:
4: Desired frequency reached 2 (Pr.02-
0 ○ ○
○
○
○
02-14
Multi-function Output 4:
R2A, R12C (Relay4)
5: Zero speed (Frequency command) 0 ○ ○
○
○
○
02-15
Multi-function Output 5:
6: Zero speed with stop (Frequency
0 ○ ○
○
○
○
02-16
Multi-function Output 6:
(MO2)
7: Over-torque (OT1) (Pr.06-05–06-07) 0 ○ ○
○
○
○
02-17
Multi-function Output 7:
8: Over-torque (OT2) (Pr.06-08–06-10) 0 ○ ○
○
○
○
02-18
Multi-function Output 8:
(MO4)
9: Drive ready 0 ○ ○
○
○
○