Chapter 12 Descriptions of Parameter SettingsC2000 Plus 
 
12.1-11-7
 
11-15 
Notch Filter Depth 
 
 
   
 Default: 0 
 
 
Settings 0–100 dB 
 
11-16 
Notch Filter Frequency 
 
 
   
 Default: 0.0 
 
 
Settings 0.0–6000.0 Hz 
 
11-47 
Notch Filter Bandwidth 
 
 
   
 Default: 0 
 
 
Settings 0–1000 Hz 
  A notch filter is a filter that attenuates a signal in a specific frequency band. 
  The notch filter also slows down the response speed in the frequency band to avoid mechanical 
resonance. 
  The higher the setting value for Pr.11-15, the better the mechanical resonance is suppressed. 
  The notch filter frequency should be equal to the mechanical frequency resonance. 
  The notch filter bandwidth is the frequency range in which the notch filter is active. 
 
 
11-17 
Forward Motor Torque Limit Quadrant I 
 
11-18 
Forward Regenerative Torque Limit Quadrant II 
 
11-19 
Reverse Motor Torque Limit Quadrant III 
 
11-20 
Reverse Regenerative Torque Limit Quadrant IV 
 
 
   
 Default: 500 
 
 
Settings 0–500% 
  FOCPG & FOC Sensorless mode:   
The motor rated current = 100%. The setting values for Pr.11-17–Pr.11-20 compare with Pr.03-
00 = 7, 8, 9, 10. The minimum value of the result after comparing is the torque limit. The diagram 
below illustrates the torque limit. 
  TQCPG and TQC Sensorless mode:   
The function of Pr.11-17–Pr.11-20 is the same as FOC; however, in this case, the torque limit 
and the torque command executes the output torque limit at the same time. Therefore, the 
minimum value between Pr.11-17–11-20 and Pr.06-12 becomes the current output torque limit. 
  VF, VFPG and SVC mode: 
Pr.11-17–Pr.11-20 limit the output current, the percentage base value is the drive’s rated current