Chapter 12 Description of Parameter SettingsMS300
469
Parameter
Description
Unit
Default
Settings
05-09
Stator inductance (Lx) for induction
motor 1 (mH)
mH
0.0
0.0–6553.5
10-25
FOC bandwidth for speed
observer
Hz
40.0
20.0–100.0
11-00
System control
513
0–65535
11-01
Per unit of system inertia
pu
256
1–65535
11-02
ASR1 / ASR2 switch frequency
Hz
7.00
5.00–599.00
11-03
ASR1 low-speed bandwidth
Hz
10
1–40 Hz (IM) /
1–100 Hz (PM)
11-04
ASR2 high-speed bandwidth
Hz
10
1–40 Hz (IM) /
1–100 Hz (PM)
11-05
Zero-speed bandwidth
Hz
10
1–40 Hz (IM) /
1–100 Hz (PM)