A-4
Specifications of VFDB Brake Unit   
Voltage Rating  230V Series  460V Series 
Model No. VFDB-□□□□ 
2015  2022 4030 4045 
Maximum applicable motor capacity (KW) 
15  22 30 45 
Peak Discharge Current 
(Ipeak)10ED%
 
40  60 40 60 
Continuous Discharge Current (A)
15  20 15 18 
Output 
Rating
 
Braking Start Voltage (DC) 
330/345/360/380/400/415±3V 660/690/720/760/800/415±3V
Power 
Supply
 
DC Voltage  200~400VDC  400~800VDC 
Over Heating of Heat Sink  Temperature Switch +95°C 
Fault output  Relay Contact 5A120Vac/28Vdc(RA.RB.RC) 
Protection 
Charge Indication  It goes off when the main loop (P-N) voltage is below 50VDC
Installation Location  Indoor (no corrosive gases or metal dusts) 
Ambient temperature 
-10°C~+50°C 
Storage Temperature 
-20°C~+60°C 
Humidity  Non-condensing below 90%RH 
Environment 
Vibration  9.8m/S
2
(1G) for < 20Hz, 2m/S
2
(0.2G) for 20 – 50Hz 
Mechanical Construction  Wall Mount IP50