4. Description of Parameters 
 
4-3
 
Parameter 
code 
Function of the parameter  Settings 
Default 
value 
VF 
FOCPG 
FOCPM 
a 
00-04 
Selection of multi-function   
display 
0: Display the output current (A) 
1: Reserved 
2: Display the actual output frequency (H) 
3: Display the DC-BUS voltage (U) 
4: Display the output voltage (E) 
5: Display the output power angle (n) 
6: Display the output power in kW (P) 
7: Display the actual motor speed rpm (r) 
8: Display the estimated output torque (%) 
9: Display the PG feedback (G) 
10: Reserved 
11: Display the signal value of the analog input 
terminal PO % (1.) 
12: Display the signal value of the analog input 
terminal PI % (2.) 
13: Display the signal value of the analog input 
terminal AUI % (3.) 
14: Display temperature of the heat sink in °C (t.) 
15: Display temperature of IGBT in °C (T) 
16: The status of digital input (ON/OFF) (i) 
17: The status of digital output (ON/OFF) (o) 
18: Reserved 
19: The corresponding CPU pin status of the digital 
input (i.) 
20: The corresponding CPU pin status of the digital 
output (o.) 
21~24: Reserved 
25: Display the signal value of the analog input 
terminal QI % (5.) 
26: Display the actual pressure value (Bar) (b.) 
27: Display the kWh value (K) 
28: Display the motor temperature (currently only 
support KTY84) (T.) 
0  ○ ○ ○
a 
00-05 
Analog output function   
selection 
0: Output frequency (Hz)  0  ○ ○ ○
 
    1: Frequency command (Hz)    ○ ○ ○
 
    2: Motor speed (Hz)    ○ ○ ○
 
    3: Output current (A)   ○ ○
 
 
4: Output voltage
 
  ○ ○ ○
 
 
5: DC Bus voltage
 
  ○ ○ ○
 
 
6: Power factor
 
  ○ ○ ○
 
 
7: Power
 
   
 
 
8: Output torque
 
   
 
 
9: PO
 
   
 
 
10: PI
 
   
 
 
11: AUI
 
  ○ ○ ○
 
 
12~20: Reserved
 
  ○ ○ ○
 
00-06 
Display the speed (rpm)   
defined by the user 
0~39999 rpm  0  ○ ○ ○
a 
00-07 
Maximum value for the   
pressure command 
0~250 Bar  250  ○ ○ ○
a 
00-08 
Maximum pressure   
feedback value 
0~400 Bar  250  ○ ○ ○