4-34
03 Digital/Analog Input/Output Parameters  a the parameter can be set 
during operation
 
 
 
Multi-function input command 3 (MI3) 
 
 
Multi-function input command 4 (MI4) 
 
 
Multi-function input command 5 (MI5) 
 
Control mode  VF  FOCPG  FOCPM   
  Factory default: 0 
 
Settings 0: No function 
   
44: Injection signal input 
   
45: Confluence/Diversion signal input   
   
46: Reserved 
   
47: Multi-level pressure PI command 1 
   
48: Multi-level pressure PI command 2 
  When the value of this parameter is set as 44, the pressure feedback is lower than the pressure 
stable region (please refer to the description of Parameter 00-26) so the flow control will be 
performed.
 
When it enters the pressure stable region, the pressure control will be performed. 
  If the setting value is 45, the confluence (OFF)/diversion (ON) function will be performed. For 
detailed operation, please refer to Chapter 2 for wiring and Chapter 3 for tuning.   
  Please refer to the description Parameters 00-36 if the setting value is 47 and 48, 
a 
 
Digital input response time 
 
Control mode  VF  FOCPG  FOCPM   
  Factory default: 0.005 
 
Settings 0.001~30.000 sec 
  This parameter is used to delay and confirm the signal on the digital input terminal.   
a 
 
Digital input operation direction 
 
Control mode  VF  FOCPG  FOCPM   
  Factory default: 0 
 
Settings 0~65535 
  This parameter defines the activation level of the input signal.   
 Bit 0 for the SON terminal, bit 2 for the EMG terminal, bit 3 for the RES terminal, bits 4~6 
correspond to MI3~MI5, respectively. 
a 
 
Multi-function output 1 (Relay 1) 
 
Control mode  VF  FOCPG  FOCPM   
  Factory default: 11 
a 
 
Multi-function Output 2 (MOI) 
 
Control mode  VF  FOCPG  FOCPM   
  Factory default: 0 
a 
 
Multi-function Output 3 (MO2) 
 
Control mode  VF  FOCPG  FOCPM   
  Factory default: 0 
 
Settings 0: No function 
 
 1: Operation indication 
 
  9: Hybrid servo drive is ready 
 
  11: Error indication 
 
  44: Displacement switch signal 
 
  45: Motor fan control signal