Pr.
Explanation
Settings
Default
15: Phase loss protection (orP)
16: IGBT overheating (oH1)
18: IGBT temperature detection failure ( tH1o)
21: Over load (oL)
22: Electronic thermal relay 1 protection (EoL1)
23: Electronic thermal relay 2 protection (EoL2)
24: Motor overheating PTC/ PT100 (oH3)
26: Over torque 1 (ot1)
27: Over torque 2 (ot2)
28: Under current (uC)
31: EEPROM read error (cF2)
33: U-phase error (cd1)
34: V-phase error (cd2)
35: W-phase error (cd3)
36: cc (current clamp) hardware error (Hd0)
37: oc (over-current) hardware error (Hd1)
40: Auto-tuning error (AUE)
41: PID loss ACI (AFE)
43: PG feedback loss (PGF2)
44: PG feedback stall (PGF3)
45: PG slip error (PGF4)
48: ACI loss (ACE)
49: External fault (EF)
50: Emergency stop (EF1)
51: External Base Block (bb)
52: Password is locked (Pcod)
54: Illegal command (CE1)
55: Illegal data address (CE2)
56: Illegal data value (CE3)
57: Data is written to read-only address (CE4)
58: Modbus transmission time-out (CE10)
61: Y-connection / -connection switch error (ydc)
62: Deceleration energy backup error (dEb)
63: Over slip error (oSL)
72: STO Loss (STL1)
76: STO (STo)
77: STO Loss 2 (STL2)
78: STO Loss 3 (STL3)
79: U-phase Over-current before run (Aoc)
80: V-phase Over-current before run (boc)

Table of Contents

Other manuals for Delta VFD2A8MS21ANSAA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD2A8MS21ANSAA and is the answer not in the manual?

Delta VFD2A8MS21ANSAA Specifications

General IconGeneral
BrandDelta
ModelVFD2A8MS21ANSAA
CategoryDC Drives
LanguageEnglish

Related product manuals