Chapter 12 Descriptions of Parameter SettingsMS300
310
Settings
Functions
Descriptions
19
External interrupt B.B.
input (Base Block)
Activates when external interrupt (B.B.) stop output occurs in the
drive.
20
Warning output
Activates when a warning is detected.
21
Over-voltage
Activates when over-voltage is detected.
22
Over-current stall
prevention
Activates when the over-current stall prevention is detected.
23
Over-voltage stall
prevention
Activates when over-voltage stall prevention is detected.
24
Operation mode
Activates when the source of operation command is not
controlled by the digital keypad (Pr.00-21 ≠ 0).
25
Forward command
Activates when the operation direction is forward.
26
Reverse command
Activates when the operation direction is reverse.
29
Output when frequency
≥ Pr.02-34
Activates when frequency is ≥ Pr.02-34
(actual output H ≥ Pr.02-34).
30
Output when frequency
< Pr.02-34
Activates when frequency is < Pr.02-34
(actual output H < Pr.02-34).
31
Y-connection for the
motor coil
Activates when Pr.05-24 = 1, the frequency output is lower than
Pr.05-23 minus 2 Hz and the time is longer than Pr.05-25.
32
∆-connection for the
motor coil
Activates when Pr.05-24 = 1, the frequency output is higher than
Pr.05-23 plus 2 Hz and the time is longer than Pr.05-25.
33
Zero speed
(actual output frequency)
Activates when the actual output frequency is 0
(the drive is in RUN mode).
34
Zero speed including
stop
(actual output frequency)
Activates when the actual output frequency is 0 or stopped.
35
Error output selection 1
(Pr.06-23)
Activates when Pr.06-23 is ON.
36
Error output selection 2
(Pr.06-24)
Activates when Pr.06-24 is ON.
37
Error output selection 3
(Pr.06-25)
Activates when Pr.06-25 is ON.
38
Error output selection 4
(Pr.06-26)
Activates when Pr.06-26 is ON.
40
Speed reached
(including Stop)
Activates when the drive’s output frequency reaches the setting
frequency or stopped.
42
Crane function
Use this function with Pr.02-34 and Pr.02-58.
Refer to Pr.02-34 and 02-58 for details and application examples.
43
Actual motor speed
detection
Activates when the motor actual speed is less than Pr.02-47.
44
Low current output
Use this function with Pr.06-71–Pr.06-73.

Table of Contents

Other manuals for Delta VFD2A8MS21ANSAA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD2A8MS21ANSAA and is the answer not in the manual?

Delta VFD2A8MS21ANSAA Specifications

General IconGeneral
BrandDelta
ModelVFD2A8MS21ANSAA
CategoryDC Drives
LanguageEnglish

Related product manuals