Chapter 14 Fault CodesMS300
613
ID
Display on LCD Keypad
Fault Name
Fault Descriptions
105
CANopen index error
(CidE)
CANopen index error
Action and Reset
Action Condition
Software detection
Action Time
Immediately act
Fault Treatment Parameter
N/A
Reset Method
Manual reset
Reset Condition
The upper unit sends a reset package to clear this fault
Record
Yes
Cause
Corrective Actions
Incorrect setting of CANopen
index
Reset CANopen Index (Pr.00-02 = 7)