Electrical Specification
Power supply voltage 5V
DC
(supplied by AC motor drive)
Insulation voltage
500V
DC
Communication wire
power consumption
0.85W
Power consumption 1W
Weight 23g
Environment
Noise immunity
ESD (IEC 61800-5-1, IEC 61000-4-2)
EFT (IEC 61800-5-1, IEC 61000-4-4)
Surge Teat(IEC 61800-5-1, IEC 61000-4-5)
Conducted Susceptibility Test (IEC 61800-5-1, IEC 61000-4-6)
Operation /storage
Operation: -10ºC–50ºC (temperature), 90% (humidity)
Storage: -25ºC–70ºC (temperature), 95% (humidity)
Shock / vibration
resistance
International standards: IEC61800-5-1, IEC60068-2-6 (TEST Fc) / IEC61800-5-1 &
IEC60068-2-27 (TEST Ea)
8-13-4 Installation
DeviceNet Connector
PIN Signal Color Definition
5
4
3
2
1
1 V+ Red DC24V
2 H White Signal+
3 S - Earth
4 L Blue Signal-
5 V- Black 0V
8-13-5 LED Indicator & Troubleshooting
There are 3 LED indicators on CMC-DN01. POWER LED displays the status of power supply. MS
LED and NS LED are dual-color LED, displaying the connection status of the communication and
error messages.
POWER LED
LED status Indication How to correct it?
OFF Power supply in abnormal status.
Check the power supply of CMC-DN01.
Green light On Power supply in normal status --