Chapter 12 Description of Parameter SettingsC2000-HS
12.1-02-30
The Local / Remote option on the digital keypad have the lowest priority.
When the PLC uses the entity DI, the corresponded function of original DI can still be triggered
through virtual terminals.
Pr. 02-74 and Pr. 02-75 can both be changed during RUN.
Pr. 02-74 and Pr. 02-75 are saved after power off.
You can choose N.O. (Pr. 02-12 bit = 0) or N.C. (Pr. 02-12 bit = 1) through the Pr. 02-12 MI mode
to trigger the virtual terminals.