Chapter 12 Descriptions of Parameter SettingsC2000 Plus 
 
12.1-07-11 
Frame  Heat Sink Fan  Capacitor Fan 
F Pr.07-19  Pr.07-19 
G Pr.07-19  No capacitor fan 
H Pr.07-19  No capacitor fan 
 
 
07-20 
Emergency Stop (EF) & Force to Stop Selection 
 
 
   
 Default: 0 
 
 
Settings  0: Coast to stop 
1: Stop by the first deceleration time 
2: Stop by the second deceleration time 
3: Stop by the third deceleration time 
4: Stop by the fourth deceleration time 
5: System deceleration 
6: Automatic deceleration 
 When the multi-function input terminal setting is set to 10 (EF input) or 18 (force to stop) and the 
terminal contact is ON, the drive stops according to the setting of this parameter.