Chapter  10  Digital  KeypadCP2000 
 
 
10-13
NOTE
 
Limitation: The charging process of the super capacitor will finish in about 6 
minutes. When the digital keypad is removed, the time setting will be in 
standby status for 7 days. After this period, the time needs to be reset.
 
9.  Keypad Locked 
 
Press 
 to lock 
 
Keypad Locked 
This function is used to lock the keypad. The main page would not display 
“keypad locked” when the keypad is locked, however it will display the 
message” please press ESC and then ENTER to unlock the keypad” when 
any key is pressed. 
 
When the keypad is locked, the main screen doesn’t 
display any status to show that. 
 
Press any key on the keypad; a screen as shown in 
image on the left will be displayed. 
 
If  ESC  key  is  not  pressed,  the  keypad  will 
automatically be back to this screen. 
 
The  keypad  is  still  locked  at  this  moment.  By 
pressing any key, a screen as shown in the image on 
the left will still be displayed. 
Press ESC for 3 seconds to unlock the keypad and 
the keypad will be back to this screen. Then each ke
 
on the keypad is functional. 
After the above steps, the keypad will not be locked when turning off the 
power and turning on the power again. 
 
10.  PLC Function 
 
Press Up/Down key to select a 
PLC’s function. 
Then press ENTER. 
 
 
 
When the PLC function is activated or stopped, the PLC status will be 
displayed on main page of Delta default setting.     
 
Option 2: Enable PLC function 
 
Default on the main screen displays PLC/RUN status 
bar. 
 
Option 3: Disable PLC function 
 
Default  on  the  main  screen  displays  PLC/STOP 
status bar 
 
If the PLC program is not available in the control 
board, PLFF warning will be displayed when 
choosing option 2 or 3.   
In  this  case,  select  option  1:  No  Function  to  clea
 
PLFF warning.