Chapter 12 Description of Parameter SettingsCP2000   
 
12.1-01-7 
 If  the  frequency  output  upper  limit  is  60  Hz  and  frequency  setting  is  also  60  Hz,  only  the 
frequency command is limited in 60 Hz. The actual frequency output may exceed 60 Hz if the 
drive starts the slip compensation function. 
 
 
Acceleration Time 1 
 
 
Deceleration Time 1 
 
 
Acceleration Time 2 
 
 
Deceleration Time 2 
 
 
Acceleration Time 3 
 
 
Deceleration Time 3 
 
 
Acceleration Time 4 
 
 
Deceleration Time 4 
 
 
JOG Acceleration Time 
 
 
JOG Deceleration Time 
  
  
Default: 10.00 
Default: 60.00 / 60.0 (22 kW and above models) 
Default: 80.00 / 80.0 (160 kW and above models) 
  Settings  Pr.01-45=0: 0.00–600.00 seconds 
    Pr.01-45=1: 0.0–6000.0 seconds 
 Use the acceleration time to determine the time required for the AC motor drive to accelerate 
from 0.00 Hz to maximum output frequency (Pr.01-00). Use the deceleration time to determine 
the time required for the AC motor drive to decelerate from maximum output frequency (Pr.01-00) 
down to 0.00 Hz. 
 The acceleration and deceleration time are invalid when using Pr.01-44 Auto-acceleration and 
Auto-deceleration Setting 
 Select the acceleration and deceleration time 1, 2, 3 and 4 with the multi-function input terminals 
settings. The defaults are acceleration and deceleration time 1. 
 With  the  enabled  torque  limits  and  stall  prevention  functions,  the  actual  acceleration  and 
deceleration time are longer than the above action time. 
 Note  that  setting the  acceleration time  too  short  may trigger  the  protection  function  (Pr.06-03 
Over-current Stall Prevention during Acceleration or Pr.06-01 Over-voltage Stall Prevention). 
 Note  that  setting  the  deceleration  time  too  short  may  cause  motor  damage  or  trigger  drive 
protection due to over-current during deceleration or over-voltage.   
 Use suitable brake resistor (refer to Section 07 Optional Accessories) to decelerate in a short 
time and prevent over-voltage. 
 When you enable Pr.01-24–Pr.01-27, the actual acceleration and deceleration time are longer 
than the setting.