Chapter 12 Description of Parameter SettingsCP2000   
 
 
12.1-02-8 
Settings  Functions  Descriptions 
68  Disable Motor 8 
69 
Preheating Command 
ON: if the preheating function is open and drive is in STOP status, 
the  preheating  function  is  executed;  until  the  contact  status 
changes to  OFF,  or  the  drive  status turns  to  RUN  and stops the 
preheating function. Refer to Pr.02-72–02-73 for detail. 
 
 
 
UP/DOWN Key Mode 
  
 
  Default: 0 
  Settings  0: Up / Down by the acceleration or deceleration time 
    1: Up / Down constant speed (Pr.02-10) 
 
 
 
Constant speed, Acceleration or Deceleration Speed of the UP/DOWN Key 
  
 
  Default: 0.001 
  Settings  0.001–1.000 Hz/ms 
 Use  when  the  multi-function  input  terminals  are  set  to  19,  20  (UP  /  DOWN  command).  The 
frequency increases or decreases according to Pr.02-09 and Pr.02-10. 
 When  Pr.02-09  is  set  to  0:  the  increasing  or  decreasing  frequency  command  (F)  operates 
according to the setting for acceleration or deceleration time (refer to Pr.01-12–Pr.01-19) 
 
 
 When Pr.02-09 is set to 1: the increasing / decreasing frequency command (F) operates 
according to the setting for Pr.02-10 (0.01–1.00 Hz/ms). 
 
 
 
Multi-function Input Response Time 
 
 
  Default: 0.005 
  Settings  0.000–30.000 sec. 
 Sets the response time of the digital input terminals FWD, REV and MI1–MI8. 
 This function is to delay and confirm the digital input terminal signal. The time for delay is also the