Chapter 2. Wiring | VFD-VJ 
 
2-23
 
Terminal  Features  Factory Setting (NPN Mode) 
Difference 
between 
VJ-A and 
VJ-B 
SON Run-Stop 
Terminal SON-COM: ON for Running; OFF for 
Stop 
 
EMG  External error input  External error input 
 
RES  Reset from error  Reset from error 
 
REV TBA  TBA 
New 
terminal 
MI3  Multi-function input selection 3 
Configured as no function in factory 
When it is ON, the input voltage is 24V
DC
 (Max: 
30V
DC
) and then input impedance is 3.75kΩ; 
when it is OFF, the tolerable leakage current is 
10μA. 
 
MI4  Multi-function input selection 4 
 
MI5  Multi-function input selection 5 
 
COM 
Common ground (Sink) for digital 
control signals   
Common ground for multi-function input 
terminals 
 
RA  Error terminal 1 (Relay N.O. a) 
Resistive load 
5A(N.O.)/3A(N.C.) 240VAC 
5A(N.O.)/3A(N.C.) 24VDC 
Inductive load 
1.5A(N.O.)/0.5A(N.C.) 240VAC 
1.5A(N.O.)/0.5A(N.C.) 24VDC 
 
RB  Error terminal 1 (Relay N.C. b) 
 
RC 
Command contact for multi-function 
output terminals (Relay) 
 
MO1 
Multi-function output terminal 1 
(photocoupler) 
The hybrid servo drive sends various 
monitoring signals by means of open-collector 
configuration.  
MO1
~
MO2
internal circuit
 
MCM
Max: 48Vdc/50mA
 
 
MO2 
Multi-function output terminal 2 
(photocoupler) 
 
 
 
 
MCM 
 
 
Common ground for Multi-function 
output terminal (photocoupler) 
 
 
 
 
 
Max 48V
DC
 50mA