Chapter 11 Summary of Parameter SettingsME300 
 
11-30 
 
Pr.  Explanation  Settings  Default 
 
07-33  Auto-restart interval of fault  0.0–6000.0 sec.
  60.0 
  07-43  Average PWM signal  1–100 times  1 
  07-44  PWM signal period  1–2000 ms  1 
 
07-62  dEb gain  0–65535  8000 
 
07-71 
Torque compensation gain 
(motor 2) 
IM: 0–10 (when Pr.05-33 = 0) 
PM: 0–5000 (when Pr.05-33 = 1 or 2) 
1 
 
07-72 
Slip compensation gain 
(motor 2) 
0.00–10.00 (default value is 1 in SVC mode)  0.00