7-4
multi-meter
Main Circuit – Transformer and Reactor
Inspection Period
Inspection Item Inspection Method
Daily Half
year
One
year
Is there any abnormal vibration or strange odor? Visual and auditory
inspection
Main Circuit – Electromagnetic Contactor and Relay
Inspection Period
Inspection Item Inspection Method
Daily Half
year
One
year
Is there any vibration sound during operation? Auditory inspection
Does the contactor have good contact property? Visual inspection
Control Circuit – Control PCB and Connectors
Inspection Period
Inspection Item Inspection Method
Daily Half
year
One
year
Are the screws and connectors loose? Fastening
Is the part with a strange odor or discolored? By smelling, visual
inspection
Is there any cracked damaged, deformed, or
corroded part?
Visual inspection
Does the capacitor have any trace of leakage or
deformation?
Visual inspection
Cooling System – Cooling Fan
Inspection Period
Inspection Item Inspection Method
Daily Half
year
One
year
Is there any abnormal sound or vibration?
Auditory and visual
inspection by manual
rotating the fan. (It is
necessary to disconnect
the power)
Are the bolts loose? Fastening
Id the part discolored due to over heating? Visual inspection
Cooling System – Ventilation Tunnel
Inspection Item Inspection Method Inspection Period