Chapter 4 Description of Parameters | VFD-VJ
4-4
Pr. Name of Parameter Setting
Factory
Setting
VF
FOCPG
FOCPM
00-07
Maximum value of the
pressure command
0~400Bar
140
00-08
Maximum feedback
pressure
0~400 Bar 250
00-09 Pressure control mode
0:Speed control
1:Pressure control
0
00-10
Speed bandwidth 1~200Hz
20
00-11
Pressure feedback
filtering time PS
0.000~1.000 second 0.000
00-12
Pressure command
filtering time
0.000~1.000 second 0.000
00-13
Flow command filtering
time
0.000~1.000 second
0.000
00-14
Percentage of the
pressure command
(Max)
0.0~100.0% 56.0
00-15
Percentage of the
pressure command (Mid)
0.0~100.0% 28.0
00-16
Percentage of the
pressure command (Min)
0.0~100.0%
0.0
00-17
Percentage of the flow
command (Max)
0.0~100.0% 100.0
00-18
Percentage of the flow
command value (Mid)
0.0~100.0% 50.0
00-19
Percentage of the flow
command (Min)
0.0~100.0%
0.0
00-20 P (proportional) gain 1 0.0~1000.0 50.0
00-21 I (integration time) 1 0.00~500.00 seconds 2.00
00-22
P (proportional) gain 2 0.0~1000.0
50.0
00-23 I (integration) time 2 0.00~500.00 seconds 2.00
00-24 P (proportional) gain 3 0.0~1000.0 50.0
00-25
I (integration) time 3 0.00~500.00 seconds
2.00
00-26 Pressure stable zone 0~100% 25
00-27 Minimum pressure 0.0~100.0% 0.1
00-28
Depressurization speed 0~100%
25